The Megger MIT1025/2 Advanced 10kV HV Insulation Resistance Tester is part of Megger’s Advanced range designed to meet the rigorous demands of industrial, utility, and maintenance environments. It is ideal for testing transformers, switchgear, motors, generators, bushings, and high-voltage cables.
With selectable test voltages of 500V, 1000V, 2500V, 5000V, and 10,000V, the MIT1025/2 can measure insulation resistance from 10kΩ to 20TΩ, with high accuracy and stability even in electrically noisy environments. It supports Polarisation Index (PI), Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Stepped Voltage (SV), and Ramp Test, which provide deep insights into insulation condition and ageing. The included guard terminal reduces surface leakage currents, thus improving measurement accuracy in contaminated or humid conditions.
The MIT1025/2 features a dedicated voltmeter capable of measuring AC and DC voltages from 30V to 660V, as well as capacitance measurement from 10nF to 25µF and leakage current measurement from 0.01nA to 6 mA. The MIT1025/2 performs reliably in high-interference environments like substations and industrial plants, with noise rejection of up to 3mA. A real-time clock and onboard memory allow users to store time/date-stamped results, which can then be downloaded via USB to a PC for reporting and compliance documentation using Megger’s PowerDB Lite software.
Featuring a large, high-contrast backlit display, readings remain readable on the MIT1025/2 even in bright sunlight or low-light conditions. Plus, an intuitive interface with dual rotary switches and a graphical quick-start guide printed inside the lid makes it easy for first-time users. The MIT10025/2 is powered by a long-lasting lithium-ion rechargeable battery that provides extended testing time and can be rapidly recharged in under 2.5 hours. Importantly, the unit can also operate directly from AC mains power, even if the battery is completely depleted, ensuring uninterrupted testing in the field.
The MIT1025/2 carries a CAT IV 600V safety rating, is certified for operation at altitudes up to 3000 metres and comes in a rugged case that includes a tough outer shell and a fire-retardant inner case, with an IP65 rating (lid closed) protecting it against dust and moisture ingress. The removable lids with Velcro-on pouches keep accessories secure and accessible and improve access to terminals during testing. Plus, a five-tier voltage warning system alerts users to hazardous conditions, and automatic capacitive discharge ensures safe handling post-test.
Included with the MIT1025/2 are two sets of 3-metre test leads (one with medium clips and one with large clips rated for 10 kV), a power lead, a screened USB cable, a quick-start guide, and a calibration certificate.
Comparing the Megger Essential, Advanced & Expert Ranges
Feature | Essential Range MIT1015 MIT515/2 |
Advanced Range MIT525/2 MIT1025/2 MIT1525/2 |
Expert Range S1-568/2 S1-1068/2 S1-1568/2 |
High Guard Termial Performance | ✔ | ✔ | ✔ |
IR | ✔ | ✔ | ✔ |
IR(t) | ✔ | ✔ | ✔ |
PI Polirasation Index | ✔ | ✔ | ✔ |
PI Predictor | ✔ | ✔ | ✔ |
DAR Dielectric Absorption Ratio | ✔ | ✔ | ✔ |
DD Dielectric Discharge | ✔ | ✔ | |
Ramp Test | ✔ | ✔ | |
RE>Act mode | ✔ | ✔ | ✔ |
PDC test | ✔ | ✔ | |
Max. voltage available | 5kV or 10kV | 5kV, 10kV or 15kV | 5kV, 10kV or 15kV |
Default maximum current | 3mA | 3mA | 6mA |
User selectable max. current values | n/a | 1mA, 3mA, 6mA (6mA only from main supply) | 1mA, 2mA, 3mA, 4mA, 5mA, 6mA (6mA from internal battery and mains supply |
Max. noise current with measurement withing accuracy spec. | 3mA (LV and MV <45kV) | 6mA (HV <230kV) | 8mA (EHV <1000kV) |
Adaptive filter | ✔ | ||
Negative current handling | ✔ | ✔ | ✔ |
Averaging filter | ✔ | ||
CAT IV 1000V | ✔ | ✔ | |
CAT IV 600V | ✔ | ✔ | ✔ |
Hazardous peak voltage detection during IR measurement | ✔ | ✔ | |
On-board - time stamped | ✔ | ✔ | |
Temperature value stored | ✔ | ✔ | |
Humidity value stored | ✔ | ||
Test results transfer via wired USB | ✔ | ✔ | |
Test result transfer via wireless Bluetooth LE | ✔ | ✔ | |
Test result live streaming via wired USB | ✔ | ✔ | |
Test result live streaming via wireless Bluetooth LE | ✔ | ✔ | |
Remote control via wired USB | ✔ | ||
New custom colour display | ✔ | ✔ | ✔ |
Carry all holdall | ✔ | ✔ | ✔ |
Deeper lid pouch | ✔ | ✔ | ✔ |
CertSuite Asset Lite compatible | ✔ | ✔ | |
CerSuite Assert compatible | ✔ | ✔ | |
Power DB Lite supplied free | ✔ | ✔ | |
Power DB Advance or Pro support | ✔ | ✔ |