Gun temperature with the Fluke 568 Infrared

  • Infrared temperature range
    566:  -40 °C to 650 °C (-40 °F to 1202 °F)
    568:  -40 °C to 800 °C (-40 °F to 1472 °F)
    Infrared accuracy
       < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
    > 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater
    Display resolution
       0.1 °C / 0.1 °F
    Infrared spectral response
       8 µm to 14 µm
    Infrared response time
       < 500 msec
    Thermocouple Type-K input temperature range
       -270 °C to 1372 °C (-454 °F to 2501 °F)
    Thermocouple Type-K input accuracy
    -270°C to -40°C:  ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F))
    -40°C to 1372°C:  ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater
    D:S (distance to measurement spot size)
    566:  30:1
    568:  50:1
    Laser sighting
       Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
    Minimum spot size
       19 mm (0.75 in)
    Emissivity adjustment
       By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
    Data storage with Date/Time stamp
    566:  20 points
    568:  99 points
    PC Interface and cable
    566:  None
    568:  USB 2.0 with FlukeView® Forms software
    Hi/Low alarms
       Audible and two-color visual
    Min/Max/Avg/Dif
       Yes
    Display
       Dot matrix 98 x 96 pixels with function menus
    Backlight
       Two levels, normal and extra bright for darker environments
    Trigger lock
       Yes
    Switchable Celsius and Fahrenheit
       Yes
    Power
    566:  2 AA/LR6 Batteries
    568:  2 AA/LR6 Batteries and USB when used with a PC
    Battery life
    If used continuously:  laser and backlight on,12 hours; laser and backlight off, 100 hours
    Operating temperature
       0 °C to 50 °C (32 °F to 122 °F)
    Storage temperature
       -20 °C to 60 °C (-40 °F to 140 °F)
    Bead thermocouple Type-K range
       -40 °C to 260 °C (-40 °F to 500 °F)
    Bead thermocouple Type-K accuracy
       ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)